Low-frequency magnetic field shielding box
EMSbox(Low frequency magnetic field compatible type)
<For simple EMI measurement and electromagnetic interference countermeasures>
Wideband shielding box that also supports low-frequency magnetic fields
made in Japan
Free design possible according to test conditions
Figure: EMSpanel cross-section (aluminum layer, magnetic material layer) 5-layer structure
⇒EMS Panel
Our unique multi-layered shielding material has broadband shielding capabilities, from static magnetic fields to several tens of GHz. Developed for pacemaker protective clothing, this material is lightweight and soft.
This shielding box is capable of shielding a wide range of frequencies, from static magnetic fields and power frequencies such as 50Hz/60Hz to millimeter waves of 60GHz and above. It is a lightweight shielding box made using our proprietary shielding material "EMS Panel." It is also insulated so that circuit board testing can be performed. It can also accommodate the installation of various I/O connectors depending on the application.
- ■Door opening image
- We have taken various measures to ensure that the joint with the door is tightly sealed and conductive.
- ■Opening, panel fixing part
- In order to ensure shielding performance, we have taken great care in designing and manufacturing the product to increase electrical airtightness.
- ■Door fixing part
- We also devise innovative fixing methods to eliminate gaps created by the door. We also design and manufacture products that take into consideration convenience and shielding performance, such as magnet types.
- ■Rear
- Various I/O connectors can be attached. Connectors can also be installed on the side. In addition, the number and types of connectors can be manufactured according to specifications.
- ■Enlarged image of the connector panel
- Depending on the type and quantity, the size of the panels will be changed and then fixed into the frame.
- ■Image from inside
- We design the installation location of the connector panel based on factors such as how the cables to be connected to the connector will be routed and the shape of the objects to be shielded inside the box.
- ■Handle processing
- We design and manufacture our products with portability in mind.
EMSpanel(material)
The 5-layer type EMSpanel has a shielding performance of 60dB (99.9%) or more over a wide frequency band from 20kHz to 2.5GHz.
1.Low Frequency Magnetic Field
2.3 layers of aluminum foil
3.High permeability magnetic material sheet, 2 layers
specification
Parts & Materials | EMSpanel | Uses a 5-layer type. Magnetic field shielding performance improves with the number of layers. | |
---|---|---|---|
Frame | Aluminum frame | ||
Partition wall | Acrylic plate protects EMS panel from scratches and damage | ||
Sealing Method | Snap lock | ||
Shielding performance | Static magnetic field | 1 EMS panel | Approximately12dB |
2 EMS panel | Approximately15dB | ||
50Hz~1kHz(magnetic field) | 1 EMS panel | 30~40dB | |
2 EMS panel | 35~45dB | ||
1kHz~10MHz(magnetic field) | 1 EMS panel | 40~50dB | |
2 EMS panel | 45~60dB | ||
10MHz~60GHz(magnetic field) | 1 EMS panel | Approximately50dB | |
2 EMS panel | Approximately60dB | ||
Conductivity of EMSpanel | Surface Resistance | 0.1Ω | |
Durability | Indoor use | Service life: Approximately 10 years. Manufacturer's warranty: 2 years | |
/Oconnector | Depends on usage conditions | Various coaxial cables, power supplies, etc. available upon request |
EMSbox reference price list (excluding tax)
Part number | Width x Depth x Height (external dimensions in mm) | Sales price (excluding tax) |
---|---|---|
EMSB450 | External dimensions:464×465×469 (Approximately30kg) ※Depth door part 40mm included 内寸:450×410×455 |
800,000yen~ Connector panel included |
EMSB450-2 | Same as above, using two 5-layer EMSpanels | 1,200,000yen~ Connector panel included |
EMSB1000 | 1014×1055×929 (Approximately80kg) ※Depth door part 40mm included 内寸:1000×1000×905 |
2,500,000yen~ Connector panel included |
EMSB1000-2 | Same as above, using two 5-layer EMSpanels | 3,750,000yen~ Connector panel included |
Custom Order※ | We can customize your product according to your intended use, such as the size and connector you require. Please request a quote or consultation below. |
Recommended for the following uses
- ・Preliminary testing can be done in the usual work area before the actual testing in the anechoic chamber.
- ・Easily create an electromagnetic wave shielding environment at research institutes such as universities and hospitals
- ・Customizable for electronic board testing, including insulation measures and I/O connector installation
- ・It is possible to create a test environment that suppresses low-frequency magnetic field noise from around the power supply.
- ・As an EMC measure to prevent malfunctions caused by electromagnetic noise from electronic devices
- ・Prevents noise interference from electromagnetic waves from mobile phone base stations
Purchase Information
▼Telephone enquiries▼
TEL 0725-53-3270
※Please be careful not to enter the wrong number.
●Reception hours: Monday to Friday 9:00 to 17:00 (excluding New Year's holidays and public holidays)