EMI Shielded Vehicle

Noise leakage prevention in accordance with the Radio Law, various EMS and EMI tests are possible

 made in Japan 


EMI Shielded Vehicleは
Recommended for businesses with the following concerns

  • ● We do not have the space to install a shielded room within our company, but we need one as an experimental facility.
  • ● We have multiple factories and research facilities and would like to test equipment at each location as necessary.
  • ● Other divisions have shielded rooms, but they are always full and there is a waiting list.
  • ● The rental fees for shielded rooms are high, reservations cannot be made immediately, and time constraints slow down development.
  • ● I want to take the time to think about ways to reduce the noise level of equipment that has failed EMI standard tests.
  • "EMI Shielded Vehicle" will solve all of these problems.

Rental of electromagnetic shield room. Arrangement of vehicles available for inspection.

Broadband high-performance electromagnetic shielding performance (has a resonant frequency band equivalent to the housing))

Electromagnetically shielded vehicles have sufficient shielding performance, allowing them to block external noise, prevent noise leakage in accordance with the Radio Law, and perform various EMS and EMI tests.

Magnetic field shielding factor from 10kHz to 10MHz

  • 1) 10 kHz ~ 50 kHz  37.79dB ~ 49.52dB
  • 2) 100kHz ~ 500 kHz  54.38dB ~ 64.95dB
  • 3) 1000kHz ~ 10MHz  69.42dB ~ 72.56dB

Electromagnetic shielding rate from 100MHz to 1GHz

  • 4) 100MHz ~ 1GHz  Horizontal polarization 51.1dB ~ 68.6dB  Vertical polarization 49.6dB ~ 68.9dB

Electromagnetic shielding rate from 1GHz to 6GHz

  • 5) 1GHz ~ 2.6GHz  Horizontal polarization 45.2dB ~ 55.6dB  Vertical polarization 41.4dB ~ 60.1dB
  • 6) 2.7GHz ~ 4.3GHz  Horizontal polarization 42.1dB ~ 52.7dB  Vertical polarization 42.3dB ~ 56.4dB
  • 7) 4.4GHz ~ 6GHz  Horizontal polarization 35.4dB ~ 46.9dB  Vertical polarization 37.4dB ~ 47.9dB
It does not take up space in the office and can be used freely 24 hours a day at a convenient location.

Shielded room available 24 hours a day, 7 days a week

It can be self-driving and set up in a factory or parking space, eliminating the need to set up shielded rooms at multiple locations, reducing capital investment and eliminating the need for installation space.

When renting an anechoic chamber or shielded room, product development takes time if multiple visits are required for the procedure of standards testing → countermeasures testing → standards testing → certification testing. However, by installing a shielded room nearby, standards testing and countermeasures testing can be performed 24 hours a day, shortening the product development period.


EMI Shielded Vehicle Specifications (Patent Pending)

Exploded view

  • 1.Aluminum panel box
  • 2.Stainless steel ceiling and walls
  • 3.Stainless steel bulkhead
  • 4.Magnetically sealed door
  • 5.Connector Panel
  • 6.LED lighting (with recessed electromagnetic wave blocking stainless steel mesh cover)
  • 7.LED lighting (external type)
  • 8.Electrical System
  • 9.Air Conditioning System
  • 10.Upper storage compartment
  • 11.Acrylic double glazed window
  • 12.Baggage door (opening: width 700 x height 900 mm)
  • 13.Private generator
  • 14.Measuring Instrument Storage Cabinet1
  • 15.Measuring Instrument Storage Cabinet2
  • 16.Measuring Instrument Storage Cabinet3
  • 17.Measuring Instrument Storage Cabinet4
  • 18.large Measuring Instrument Storage Cabinet5

Dimensions Width (W) x Depth (D) x Height (H)

Electromagnetic shield room interior dimensions

1930X1990X1880mm

Operation room interior dimensions

1930X1490X1930mm


- Power Supply and Connector Panel Specification Table -

External power supply (according to customer's equipment)

Specifications

specification

Supply voltage

100V

Maximum power

1500W

Power Breaker

Single phase, two wire、100V、50/60Hz、15A

Self-powered battery 【TEC29】

Specifications

specification

Supply voltage

230V士10%

Reduce pressure with down transformer

100V士10%

Maximum Continuous Power

2600W士5%

Power Breaker

Single phase, two wire、100V、50/60Hz、30A

frequency

50/60Hz士1%

DC current

12V/10A

Total Harmonic Distortion(THD)

0.01

Fuel consumption (gasoline)

230g/HP/h

Connector Panel

N type x 2, BNC type x 3, USB x 1, LAN x 2, Through tube inner diameter q)25 x 1, Power noise filter inlet x 1


- CREA 5.3 Base vehicle specification -

base Toyota Camroad
engine
Diesel turbo
1KD(3000cc) 
transmission 4-speed floor-AT
Maximum power 144PS/3400rpm
Maximum torque 30.6kg/1200~3200rpm
full length 5190mm
Width 2070mm
Height 2910mm/2WD 、4WD
Alternator 130A
Air conditioning Front air conditioner
Heater Front only
Front seats Fabric upholstery 3-seater
Seat reclining D seats + P seats
audio Radioless + 2 speakers
Central door locking D seats + P seats
Windshield wipers Intermittent type (with timer)
Power windows Standard Equipment
ABS 4WD
Minimum turning radius 4.9m
Fuel tank 80L
Sun visor D seats + P seats
Airbags D seats + P seats
Side glass UV-cut glass
mirror P-seat electric storage + P-seat long stay
Wide tread Standard Equipment
Immobilizer Standard Equipment(Anti-theft devices)
G Package Standard Equipment
Wood grain panel, passenger sun visor, wireless door lock, intermittent windshield wipers with timer, windshield with top shade

 Back to Top

Price (excluding tax and other fees) and delivery time

Mobile shield room unit price 25 million yen※
Delivery time (production factory capacity is insufficient) Orders suspended. Rental only.

※The price is for the model product (specification listed on the website).

Rental Information



Please use it not only for shielded room use but also for standard tests and countermeasure tests.
We have an EMI countermeasure test system available, which allows us to measure the relative noise level exceeded in an anechoic chamber.

To the corresponding standard test

 Back to Top