Human Exposure Protection Test Data

The MG Military Suit was subjected to radiated emission testing and its human exposure protection performance was evaluated using the following procedure. The electromagnetic wave shielding material "MG Net" used in the MG Military Suit is double-layered (shielding performance 32-40dB), and reduces the electric field strength almost uniformly inside the human body.※If the shielding performance is too high (60dB or more), the effects of reflection and resonance will become greater, amplifying electromagnetic waves inside the human body and causing hot spots.

  •  1 The bilog antenna that irradiates electromagnetic waves was placed 0.45 m vertically in the center of the back of the human body phantom and 0.9 m horizontally to the right, irradiating horizontally and vertically polarized waves.
  •  2 Receiving probes were placed on the head and chest of the human body phantom, and the electric field strength was measured in the frequency range of 270 MHz to 925 MHz.
  •  3 Receiving probes were placed on the head and chest of the human-body phantom, and the electric field strength was measured in the frequency range of 270 MHz to 925 MHz while the phantom was wearing an "MG military suit."
  •  4 The above measurement results confirmed the electromagnetic protective performance of the "MG Military Suit."

MG Military Suit Radiated Emissions Test

Date and Time March 19, 2020 10:00~17:00
place Osaka Prefectural Technology Research Institute: Radio Wave Anechoic Chamber
the purpose The electromagnetic field strength in space and the electromagnetic field strength inside a body-shaped phantom when the "MG Military Suit" was worn by a body-shaped phantom were measured and compared to evaluate the performance of the "MG Military Suit."

Table 1 Test frequencies

Exam number

frequency(MHz)

270

420

500

790

925


Table 2. Specifications of the equipment used in the test


Device name

Manufacturer

Model

Identification number

Main characteristics

Electromagnetic field sensor (main unit)

NARDA

NBM-520

C-0130

Frequency range:100 kHz~3 GHz

Measurement range:185 mV/m~300 V/m

Electromagnetic field sensor (probe)

NARDA

EF0391

A-0823

Signal Generator

Rohde & Schwarz

SMB100A

105731

frequencyrange:9 kHz~3.2 GHz

amplifier

PRANA

MT200

1176

frequencyrange:80 MHz~1 GHz

Maximum power:200 W

Transmitting Antenna

Schwarzbeck

VULP9118D

9118D631

frequencyrange:95 MHz~1.5 GHz


Table 3. Measurement values ​​when the electromagnetic field sensor was placed on the right temple

Transmitting antenna polarization plane

Horizontal polarization

Electric/magnetic fields

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

57.5

7.79

86.4

0.151

0.0207

86.3

420

67.8

4.74

93.0

0.180

0.0127

92.9

500

51.9

15.9

69.4

0.137

0.0422

69.3

790

56.8

13.2

76.7

0.150

0.0350

76.7

925

71.3

16.9

76.3

0.189

0.0443

76.6

Transmitting antenna polarization plane

Vertical polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

33.0

5.27

84.0

0.0875

0.0139

84.2

420

25.6

10.9

57.6

0.0679

0.0289

57.5

500

27.3

9.00

67.0

0.0721

0.0240

66.8

790

30.8

10.0

67.6

0.0816

0.0265

67.6

925

43.6

6.37

85.4

0.115

0.0169

85.3


Table 4. Measurements when the magnetic field sensor is placed on the dovetail

Transmitting antenna polarization plane

Horizontal polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

127

11.3

91.1

0.333

0.0296

91.1

420

93.0

13.8

85.2

0.246

0.0358

85.5

500

58.6

5.11

91.3

0.155

0.0136

91.3

790

51.9

12.8

75.4

0.138

0.0337

75.6

925

55.3

13.8

75.1

0.147

0.0369

74.9

Transmitting antenna polarization plane

Vertical polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

36.3

6.70

81.6

0.0965

0.0176

81.7

420

11.0

6.12

44.1

0.0290

0.0164

43.5

500

14.0

7.45

46.7

0.0370

0.0199

46.3

790

21.2

7.52

64.5

0.0561

0.0200

64.3

925

26.5

9.64

63.6

0.0701

0.0255

63.6


Table 5. Measurements when the magnetic field sensor was placed on the back of the head

Transmitting antenna polarization plane

Horizontal polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

29.8

2.24

92.5

0.0782

0.00585

92.5

420

32.1

2.65

91.8

0.0852

0.00694

91.9

500

29.3

5.12

82.5

0.0779

0.0139

82.2

790

25.9

3.66

85.9

0.0687

0.00965

86.0

925

44.4

9.61

78.4

0.118

0.0248

79.0

Transmitting antenna polarization plane

Vertical polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

31.2

0.738

97.6

0.0828

0.00198

97.6

420

36.1

1.37

96.2

0.0958

0.00364

96.2

500

37.5

2.22

94.1

0.0993

0.00591

94.0

790

44.9

3.74

91.7

0.119

0.00995

91.6

925

62.0

2.67

95.7

0.164

0.00715

95.6


Table 6. Measurement values ​​when the magnetic field sensor is placed in the center of the back


Transmitting antenna polarization plane

Horizontal polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

60.1

1.99

96.7

0.158

0.00545

96.5

420

57.8

1.95

96.6

0.153

0.00525

96.6

500

65.3

8.35

87.2

0.174

0.0227

86.9

790

56.8

6.56

88.4

0.151

0.0179

88.1

925

69.5

11.5

83.5

0.185

0.0306

83.5

Transmitting antenna polarization plane

Vertical polarization

electric field/magnetic field

electric field(V/m)

magnetic field(A/m)

frequency(MHz)

No protective clothing

Protective clothing available

Decay Rate(%)

No protective clothing

Protective clothing available

Decay Rate(%)

270

24.0

3.62

84.9

0.0637

0.00946

85.2

420

27.2

3.71

86.4

0.0723

0.00965

86.7

500

28.5

3.25

88.6

0.0755

0.00847

88.8

790

39.5

2.97

92.5

0.105

0.00778

92.6

925

30.1

4.15

86.2

0.0797

0.0106

86.7

 

Electromagnetic wave shielding material MGnet